Techniques and Technical Tips
  Unexpected Artifact in Liver Biopsies - Page 4
Response from:
EO Hoffmann (
ehoffm@lsumc.edu)
Date: Wednesday, July 02, 1997 08:58 AM

We had the same problem with stat renal transplant biopsies (1). The center of the needle biopsy is poorly fixed and does not take the toluidine blue due to poor OsO
4 fixation. The problem may be avoided by microwave fixation (2&3) or just by fixation in warm fixative (1).

References:

  1. Flores TR, Hoffmann EO, Velasquez,M: Stat HRLM-TEM techniques for transplant renal biopsies. J Histotechnol. Submitted for publication June, 1997.
  2. Ted Pella, Inc: Microwave-assisted rapid tissue processing. Workshop booklet. P.O. Box 492477. Redding CA 96049, 1996.
  3. Giberson RT, Smith RL, Demaree RS: Three hour microwave tissue processing for transmission electron microscopy: From unfixed tissue to sections. Scanning 17, suppl. V:26-27, 1995.

Reply to: tflore@lsumc.edu